For screen reader problems with this website, please call214-396-62902 1 4 3 9 6 6 2 9 0Standard carrier rates apply to texts.
Thoughtful Integrations
214-396-6290
The SurgeX SX-1115-RT and SX-1120-RT rack mount products offer comprehensive power protection and conditioning to safeguard AV equipment from harmful electrical transients that can cause malfunction and downtime. They allow technicians to turn equipment on or off remotely for quick reboots that can reduce service calls.
Product Weight (lbs.) | 11 |
---|---|
Depth (in.) | 10.5 |
Width (in.) | 19 |
Height (in.) | 1.75 |
Number Of Outlets | 9 |
Load Rating | 20A |
---|---|
Voltage Rating | 120V |
Power Requirement (No Load) | 15 W |
Surge Let-Through Voltage (6000 Volt Surge) | 0 Volts |
Maximum Applied Surge Voltage | 6000 Volts |
Maximum Applied Surge Currrent | Unlimited (due to current listing) |
Maximum Applied Surge Energy | Unlimited (due to current listing) |
Endurance (C62.41-1991 category B3 Pulses) | 1 KV > 500,000; 3 KV > 10000; 6 KV > 1000 |
Under-Voltage Auto Shutdown | 90V |
Over-Voltage Auto Shutdown | 145V |
Over-Current Auto Shutdown | Circuit Breaker |
Auxiliary Relay Outputs | 2 x Screw Terminal |
Contact Closure Input | 2 x Screw Terminal |
Dimensions | 1.75" H x 19" W x 10.5" D |
Weight | 11 lbs |
Temperature Range | 5C to 35C |
Humidity Range | 5% to 95% R.H. Non-Condensing |
Agency Listings | Conforms to UL Std 1283 and 1449, Certified to CSA Std C22.2 No.8 |
Call for Best Price
Remote turn-on
Thermal circuit breaker overload protection
Self-test circuit with visual indicator
Magnetic shielding steel enclosure
Non-sacrificial components
9’ grounded 3-wire cord
Featuring Advanced Series Mode technology, they eliminate all surge energy to make sure the connected equipment is protected from surges, spikes, electrical transients and noise. They do not produce ground contamination or common-mode disturbances that cause hissing sounds and pixelation on AV equipment.
SurgeX’s 360 degrees of advanced power protection also encompasses catastrophic over/under voltage shutdown, inrush current elimination, and impedance tolerant noise filtering to ensure equipment stays up and running without disruption and the power quality remains consistent.
SurgeX offers the highest level of protection to guarantee equipment receives clean power and functions properly.
Product Weight (lbs.) | 11 |
Depth (in.) | 10.5 |
Width (in.) | 19 |
Height (in.) | 1.75 |
Number Of Outlets | 9 |
Load Rating | 20A |
Voltage Rating | 120V |
Power Requirement (No Load) | 15 W |
Surge Let-Through Voltage (6000 Volt Surge) | 0 Volts |
Maximum Applied Surge Voltage | 6000 Volts |
Maximum Applied Surge Currrent | Unlimited (due to current listing) |
Maximum Applied Surge Energy | Unlimited (due to current listing) |
Endurance (C62.41-1991 category B3 Pulses) | 1 KV > 500,000; 3 KV > 10000; 6 KV > 1000 |
Under-Voltage Auto Shutdown | 90V |
Over-Voltage Auto Shutdown | 145V |
Over-Current Auto Shutdown | Circuit Breaker |
Auxiliary Relay Outputs | 2 x Screw Terminal |
Contact Closure Input | 2 x Screw Terminal |
Dimensions | 1.75" H x 19" W x 10.5" D |
Weight | 11 lbs |
Temperature Range | 5C to 35C |
Humidity Range | 5% to 95% R.H. Non-Condensing |
Agency Listings | Conforms to UL Std 1283 and 1449, Certified to CSA Std C22.2 No.8 |